Interceptor® Pressure Test Kit

Style Number: 002000P-CETranslations
  • Use as part of a regular maintenance procedure to confirm leak-tightness of your Interceptor® gas-tight suits.
  • Includes everything required in a single, tough and durable carry case.
  • Contents include pressure blower, magnehelic pressure gauge, hoses and fittings for connection to suit and stop watch.
  • Training on conducting a pressure test available from Lakeland’s sales teams free of charge.
Colors
Case Size
1/case

Resources

Interceptor® Plus Physical Properties
Physical PropertyTest MethodUnitsTest Results
Abrasion ResistanceEN 530Cycles>2000 / Class 2
Flex CrackingEN 7854Cycles>1000 / Class 1
Flex Cracking at -30CEN 7854Cycles>200 / Class 2
Trapezoidal Tear - cdISO 9073Newtons220N / Class 6
Trapezoidal Tear - mdISO 9073Newtons246N / Class 6
Tensile Strength - cdEN 13934Newtons396N / Class 4
Tensile Strength - mdEN 13934Newtons630N / Class 5
Puncture ResistanceEN 863Newtons43.6N / Class 2
Seam StrengthEN 13935Newtons655N / Class 6
Interceptor® Plus Permeation Data
Challenge ChemicalCAS NumberPhysical StateNormalized Breakthrough Time
1,3-Butadiene106-99-0Liquid>480
2,2,2-Trichloroethanol115-20-8Liquid>480
2,3 Dichloro- 1Propene78-88-6Liquid>480
2,4-Dichlorophenol120-83-2Liquid>480
2,4-dichlorophenoxy Acetic Acid94-75-7Liquid>480
4-Bromofluorobenzene460-00-4Liquid>480
Acetic Acid64-19-7Liquid>480
Acetone67-64-1Liquid>480
Acetonitrile75-05-8Liquid>480
Acetyl Chloridein75-36-5Liquid>480
Acrolein107-02-8Liquid>480
Acrylic Acid79-10-7Liquid>480
Acrylonitrile107-13-1Liquid>480
Allyl Chloride107-05-1Liquid>480
Ammonia7664-41-7Liquid>480
Ammonium Fluoride12125-01-8Liquid>480
Bromine7726-95-6Liquid98
Carbon Disulfide75-15-0Liquid>480
Chlorine7782-50-5Gas>480
Dichloromethane75-09-2Liquid>480
Diethylamine109-89-7Liquid>480
Dimethylformamide68-12-2Liquid>480
Ethyl Acetate141-78-6Liquid>480
Ethylene Oxide75-21-8Gas>480
Hexane110-54-3Liquid>480
Hydrofluoric Acid7664-39-3Liquid>480
Hydrogen Chloride7647-01-0Gas>480
Hydrogen Fluoride7664-39-3Gas>480
Methanol67-56-1Liquid>480
Methyl Chloride74-87-3Gas>480
Nitrobenzene98-95-3Liquid>480
Phosphorus Pentachloride10026-13-8Liquid>480
Sodium Hydroxide1310-73-2Liquid>480
Sulfuric Acid7664-93-9Liquid>480
Sulphur Dioxide7446-09-5Gas>480
Sulphuryl Chloride7791-25-5Liquid>480
Tetrachloroethylene127-18-4Liquid>480
Tetrahydrofuran109-99-9Liquid>480
Thionyl Chloride7719-09-7Liquid97
Toluene108-88-3Liquid>480
Vinyl Chloride75-01-4Liquid>480

NOTE: Permeation test data relates to "Normalised Breakthrough" which measures the time for permeation rate to reach a specific speed (In CE EN 6529 testing, 1.0µg/min/cm2 and in US testing, 0.1µg/min/cm2). This does not indicate when the chemical first breaks through the fabric and is not an indication of how long the suit can be safely used as the chemical may have permeated through the fabric before the Normalised Breakthrough time. This might be critical is cases of chemicals with high toxicity. For safe-use indications Safe-Use tines can be calculated manualy or refer to Permasure®.