Pyrolon® CRFR Apron with ties
Style Number: ECR025TranslationsOuter FR PVC barrier film laminated to proprietary nonwoven substrate of viscose rayon – 144gsm. Combines Flame Retardency to EN 14116 with Type 3 & 4 Partial Body chemical protection. Fabric will not ignite or burn: chars at temperature lower than its ignition point.
- Flame retardant apron with neck loop and waist ties.
- Exceptionally soft and flexible fabric for superior comfort.
- Pyrolon® CRFR will not protect against flames and heat when worn on its own but is designed to be worn over woven FR garments without compromising flame and heat protection.
Features: Attached ties
- Colors
- Sizes
- SM - 3XL
- Case Size
- 25/case
- Seam
- Serged/Taped
Resources
- Documents
- Sizing Charts
- Page Links
- Images
- Translations
Catalogs
Pyrolon® CRFR Documents
- Hojas de tiffen, guías de selección y hojas de datos con certificación CE
- Fiches de Produits, Guides de Sélection et Fiches d'information Certifiés CE
- CE-zertifizierte Produktblätter, Auswahlhilfen und Datenblätter
- CE-gecertificeerde productbladen, selectiegidsen en informatiebladen
- Arkusze produktów z certyfikatem CE, przewodniki wyboru i zestawienia informacji
- Schede prodotto, guide alla selezione e schede informative certificate CE
- Español - EU Galeria de Videos
- Français - EU Galerie Vidéo
- Deutsch - EU Videogalerie
- Nederlands - Video Gallerij
- Polska - Galeria Wideo
Physical Property | Test Method | Units | Test Results |
---|---|---|---|
Abrasion Resistance | EN 530 | >2000 cycles/Class 6 | |
Burst Strength | ISO 2960 | 118kPa / Class 2 | |
Puncture Resistance | EN 863 | 14.7N / Class 2 | |
Tensile Strength - cd | ISO 13934 | 133N / Class 2 | |
Tensile Strength - md | ISO 13934 | 81N / Class 2 | |
Trapezoidal Tear - cd | EN 9073 | 34.3N / Class 2 | |
Trapezoidal Tear - md | EN 9073 | 48N / Class 3 | |
Trapezoidal Tear - mean | EN 9073 | 41.15N / Class 3 | |
Flex Cracking Resistance | ISO 7854 | <100,000 flexes/Class 5 | |
Hydrostatic Head | ISO 811 | 741cm | |
Seam Strength | EN 5082 | <180N / Class 4 |
Physical properties data is based on standard tests required by CE certification designed to allow easy comparison of the strength, durability and robustness of different garments. Lakeland's "Guide to Type 5 & 6 Coveralls" contains easy reference comparison tables of Lakeland garments with main competitors. A glossary with brief explanation of these tests can be found in Lakeland’s “Guide to Chemical Suit Selection”.
Chemical Test | CAS Number | Physical State | Test Results |
---|---|---|---|
Acetone | 67-64-1 | Liquid | >60 |
Acetaldehyde | 75-07-0 | Liquid | >60 |
Gasoline | MIXTURE | Liquid | >60 |
Sodium Hypochlorite | 7681-52-9 | Liquid | >60 |
Sodium Hydrosulfide | 207683-19-0 | Liquid | >60 |
Acetic Acid | 64-19-7 | Liquid | >60 |
Diphenyloxide | 101-84-8 | Liquid | >60 |
Bipphenyl | 92-52-4 | Liquid | >60 |
hHexamethylene Diisocyanate | 822-06-0 | Liquid | >60 |
Penetration is the process by which a liquid (or dust) will pass through the fabric via holes or gaps in its structure. It is generally measured using visual methods and is suitable for garments designed to protect against chemicals with lower levels of toxicity - those that require larger volumes to cause harm. (For combined chemical / FR protection against higher hazard chemicals see Pyrolon® CBFR)
For Pyrolon® CRFR & TPCR garments, because the resistance against permeation by chemicals is limited (see permeation test results) more extensive testing has been conducted according to the US ASTM F903 Penetration Test. This measures the time until a visible breakthrough of the chemical through the fabric is apparent. Pyrolon CRFR and TPCR combine chemical resistance with FR properties (certified to EN 14116 Index 1: unlike standard chemical suits the fabric will not ignite and burn* and so can be worn OVER Thermal Protective Garments WITHOUT compromising thermal protection. Whilst Pyrolon CRFR and TPCR have a limited permeation barrier, depending on the chemical toxicity, a penetration test result may be a good indication of suitable protection where the fire or flammability risk is of primary or major concern.